• sns01
  • sns03
  • sns02

Kontaktor vakum

  • Ckj5-63a Ac Low Voltage Vacuum Contactor

    Ckj5-63a Ac Low Voltage Vacuum Kontaktor

    Parameter Téknis Utami Modél Dihaturkeun voltase (V) Dihaturkeun arus utama ayeuna (A) Parameter kontak utama Daya tahan coltage coltage V (nilai épéktip) Sirkuit Kontrol sirkuit utama Jarak (mm) Overtravel (mm) Tekanan akhir (N) Main circuit Auxiliary circuit control sirkuit CKJ5-63 1140 36,110,220,380 63 1.6 ± 0,2> 0,8 30 ± 5 4200 2500 2000 Kapasitas Ngalakukeun Modél Kapasitas pegatna Ngawatesan arus (A) waktos hirup listrik Mékanis ...
  • Ckg4-160,250,400,630/12-5 Ac High Voltage Vacuum Contactor

    Ckg4-160,250,400,630 / 12-5 Ac Tegangan Kontak Vakum Tinggi

    Parameter Téknis Utami Model CKG4-160-630 / 12-5 Main circuit dipeunteun voltase (KV) 12 12 12 12 Main circuit dipeunteun ayeuna (A) 160 250 400 630 Main circuit damel kamampuan (A / 100 Ops.) 1600 2500 4000 6300 Kamampuh ngadamel-circuit utama (A / 25 Ops.) 1280 2000 3200 5000 Kamampuh putus maksimal (A / 3 Ops.) 3200 3200 4000 6300 Kahirupan mékanis (Ops.) 1000000 1000000 1000000 1000000 Tegangan tahan-frékuénsi listrik pikeun sirkuit utama ( kV) 42 42 ...
  • Jcz5-7.2d(J)/160,250,400,630 Ac High Voltage Vacuum Contactor

    Jcz5-7.2d (J) / 160,250,400,630 Ac Kontaktor Vakum Tegangan Tinggi

    Parameter Téknis Utami Modél Dihaturkeun voltase (V) Dihaturkeun arus utama ayeuna (A) Parameter kontak utama Daya tahan coltage coltage V (nilai mujarab) Main circuit Control circuit Distance (mm) Overtravel (mm) pressure Final (N) Main circuit Auxiliary circuit control sirkuit JCZ5-7.2D (J) / 160 7200 100.22 160 4.5 ± 0.5 1.5 ± 0.5> 85N 32000 2500 2000 JCZ5-7.2D (J) / 250 7200 100.22 250 4.5 ± 0.5 1.5 ± 0.5> 85N 32000 2500 2000 JCZ5-7.2 D (J) / 400 7200 100.22 400 4.5 ± 0.5 1.5 ± 0 ...
  • Jcz5-12d(J)/160,250,400,630 Ac High Voltage Vacuum Contactor

    Jcz5-12d (J) / 160,250,400,630 Ac Kontaktor Vakum Tegangan Tinggi

    Parameter Téknis Utami Modél Dihaturkeun voltase (V) Dihaturkeun arus utama ayeuna (A) Parameter kontak utama Daya tahan coltage coltage V (nilai épéktip) Sirkuit Kontrol sirkuit utama Jarak (mm) Overtravel (mm) Tekanan akhir (N) Main circuit Auxiliary circuit control sirkuit JCZ5-12D (J) / 160 12000 100.22 160 5 ± 0.5 1.5 ± 0.5> 85N 42000 2500 2000 JCZ5-12D (J) / 250 12000 100.22 250 5 ± 0.5 1.5 ± 0.5> 85N 42000 2500 2000 JCZ5-12D (J ) / 400 12000 100.22 400 5 ± 0,5 1,5 ± 0,5> 85 ...
  • Ckg4-160,250,400,630/12-4 Ac High Voltage Vacuum Contactor

    Ckg4-160,250,400,630 / 12-4 Ac tegangan tinggi Kontaktor vakum

    Parameter Téknis Utami Modél CKG4-160-630 / 12-4 Tegangan sirkuit utama (KV) 12 12 12 12 Main circuit dipeunteun ayeuna (A) 160 250 400 630 Main circuit main kemampuan (A / 100 Ops.) 1600 2500 4000 6300 Kamampuh ngadamel-circuit utama (A / 25 Ops.) 1280 2000 3200 5000 Kamampuh putus maksimal (A / 3 Ops.) 3200 3200 4000 6300 Kahirupan mékanis (Ops.) 1000000 1000000 1000000 1000000 Tegangan tahan-frékuénsi listrik pikeun sirkuit utama ( kV) 42 ...
  • Ckg4-160,250,400,630/12-2 Ac High Voltage Vacuum Contactor

    Ckg4-160,250,400,630 / 12-2 Ac Tegangan Kontak Vakum Tinggi

    Parameter Téknis Utami Modél CKG4-160-630 / 12-2 Tegangan sirkuit utama (KV) 12 12 12 12 Main circuit dipeunteun ayeuna (A) 160 250 400 630 Main circuit main kemampuan (A / 100 Ops.) 1600 2500 4000 6300 Kamampuh ngadamel-circuit utama (A / 25 Ops.) 1280 2000 3200 5000 Kamampuh putus maksimal (A / 3 Ops.) 3200 3200 4000 6300 Kahirupan mékanis (Ops.) 1000000 1000000 1000000 1000000 Tegangan tahan-frékuénsi listrik pikeun sirkuit utama ( kV) 42 42 ...
  • Ckg4-160,250,400,630/12-1 Ac High Voltage Vacuum Contactor

    Ckg4-160,250,400,630 / 12-1 Ac High Voltage Vacuum Contactor

    Parameter Téknis Utami Model CKG4-160-630 / 12-1 Main circuit dipeunteun voltase (KV) 12 12 12 12 Main circuit dipeunteun ayeuna (A) 160 250 400 630 Main circuit damel kamampuan (A / 100 Ops.) 1600 2500 4000 6300 Kamampuh ngadamel-circuit utama (A / 25 Ops.) 1280 2000 3200 5000 Kamampuh putus maksimal (A / 3 Ops.) 3200 3200 4000 6300 Kahirupan mékanis (Ops.) 1000000 1000000 1000000 1000000 Tegangan tahan-frékuénsi listrik pikeun sirkuit utama ( kV) 42 42 ...
  • Ckg4-12/160,250,400,630 Ac High Voltage Vacuum Contactor

    Ckg4-12 / 160,250,400,630 Ac High Voltage Vacuum Contactor

    Parameter Téknis Utami Modél Dihaturkeun voltase (V) Dihaturkeun arus utama ayeuna (A) Parameter kontak utama Daya tahan coltage coltage V (nilai resistansi) Sirkuit utama Control Circuit Jarak (mm) Overtravel (mm) Tekanan akhir (N) Main circuit Auxiliary circuit control sirkuit CKG4-12 / 160 12000 100.220,380 160 5 ± 0,5 5 ± 0,2> 85N 42000 2500 2000 CKG4-12 / 250 12000 100.220,380 250 5 ± 0,5 5 ± 0,2> 85N 42000 2500 2000 CKG4-12 / 400 12000 100 ...
  • Ckg3-7.2/160,250,400,630-5 Ac High Voltage Vacuum Contactor

    Ckg3-7.2 / 160,250,400,630-5 Ac Kontaktor Vakum Tegangan Tinggi

    Parameter Téknis Utami Modél CKG3-7.2 / 160-630-5 Tegangan sirkuit utama (KV) 7.2 7.2 7.2 7.2 Sirkuit utama arus dipeunteun (A) 160 250 400 630 Pangabisa ngadamel sirkuit utama (A / 100 Ops.) 1600 2500 4000 6300 Kamampuh ngadamel-circuit utama (A / 25 Ops.) 1280 2000 3200 5000 Kamampuh putus maksimal (A / 3 Ops.) 3200 3200 4000 6300 Kahirupan mékanis (Ops.) 1000000 1000000 1000000 1000000 Tegangan tahan-frékuénsi listrik pikeun sirkuit utama ( kV) ...
  • Ckg3-7.2/160,250,400,630 Ac High Voltage Vacuum Contactor

    Ckg3-7.2 / 160,250,400,630 Ac High Voltage Vacuum Contactor

    Parameter Téknis Utami Model CKG3-7.2 / 160-630 Main circuit dipeunteun voltase (KV) 7.2 7.2 7.2 7.2 Main circuit dipeunteun ayeuna (A) 160 250 400 630 Main circuit damel kamampuan (A / 10 Ops.) 1600 2500 4000 6300 Main circuit putus pangabisa (A / 10 Ops.) 1280 2000 3200 5000 Kamampuh putus maksimal (A / 3 Ops.) 3200 3200 4000 6300 umur mékanis (Ops.) 1000000 1000000 1000000 1000000 Téknik konci hirup (Ops.) 100000 100000 100000 100000 ...
  • Ckg3-7.2/160,250,400,630-4 Ac High Voltage Vacuum Contactor

    Ckg3-7.2 / 160,250,400,630-4 Ac Kontak Voltase Vakum Luhur

    Parameter Téknis Utami Modél CKG3-7.2 / 160-630-4 tegangan dipeunteun sirkuit utama (KV) 7.2 7.2 7.2 7.2 Sirkuit utama arus dipeunteun (A) 160 250 400 630 Pangabisa ngadamel sirkuit utama (A / 100 Ops.) 1600 2500 4000 6300 Kamampuh ngadamel-circuit utama (A / 25 Ops.) 1280 2000 3200 5000 Kamampuh putus maksimal (A / 3 Ops.) 3200 3200 4000 6300 Kahirupan mékanis (Ops.) 1000000 1000000 1000000 1000000 Tegangan tahan-frékuénsi listrik pikeun sirkuit utama ( kV) ...
  • Ckj20-630,800/2000a Ac Vacuum Contactor

    Ckj20-630,800 / 2000a Ac Vacuum Kontaktor

    Parameter Téknis Utami Model CKJ20-630 / 1140 CKJ20-800 / 1140 Main circuit dipeunteun voltase (V) 1140 1140 Main circuit dipeunteun ayeuna (A) 630 800 Main circuit damel kamampuan (A / 10 Ops.) 6000 8000 Main circuit break-making kamampuan (A / 10 Ops.) 4800 6400 Kamampuh putus maksimal (A / 3 Ops.) 6000 7500 Umur listrik AC3 (Juta kali) 90 Umur listrik AC4 (Juta kali) 6 Umur mékanis (Juta kali) 300 Dihaturkeun frekuensi operasi AC3 ( Ops./h) 600 R ...
12 Teras> >> Halaman 1/2