Kapasitor Daya Tegangan Tinggi BAM
Aplikasi sareng Standar:
Kapasitor tegangan tinggi utamana dipaké dina sistem AC Power kalawan 50Hz pikeun ngaronjatkeun faktor kakuatan. Kinerja saluyu sareng GB 3083.2-89 《Kapasitor shunt tegangan tinggi》 sareng IEC 60871-1987.
GB / T11024-2010 Standar Nasional 《Tegangan dipeunteun 1kV atanapi saluhureuna kapasitor shunt pikeun sistem kakuatan AC
JB/7112-2000 Standar Industri Mesin 《Dirakit HV Shunt Kapasitor
DL/T628-1997 Standar Industri Daya Listrik 《Dirakit HV Shunt Kapasitor Mesen Syarat Téknis
Kaayaan Pamakéan:
1.Altitude: kirang ti 1000m; Suhu ambient: -40 ℃ ~ + 40 ℃.
2.No Geter mékanis telenges, euweuh gas ngabahayakeun sarta uap, euweuh listrik, sarta ngabeledug, sarta lebu ngabeledug di lokasi.
3.Tegangan operasi kontinyu: 1,00 Un, max jangka panjang, Leuwih tegangan: less.1 Un.
4.Stabil leuwih-ayeuna (kaasup harmonik ayeuna) kirang 1,3 Di.
5.With tegangan nangtung: antara terminal 2.15, waktos dipeunteun tegangan pikeun 10 detik, antara terminal jeung wadahna 42kV pikeun 10 detik.
ciri teknis utama:
1.Tegangan dipeunteun: 6.3kV, 6.6kV, 6.6/√3kV, 7.96kV, 10.5kV, 11kV, 11kV, 11/√3kV, mangga dituduhkeun dina urutan upami Anjeun hoyong kapasitas husus sejenna.
Kapasitas 2.Rated: 33~334kvar punten dituduhkeun dina urutan upami anjeun hoyong kapasitas husus sejenna.
3.Kasabaran kapasitas: -5 ~ 15%.
4.Loss malaikat nilai tangensial: pilem & papaer sedeng tg θ≦0.08%, pilem sedeng tg θ≦0.05%.
5.Withstand tegangan: eta can mampuh AC2.15 atanapi DC4.3 kali dipeunteun tegangan antara pales kapasitas, panungtungan ngeunaan 10s tanpa putus atawa flash, BIL: 6kV (30kV), 10kV (42Kv).
6.Free ngurangan: eta boga lalawanan jero, 10min sanggeus motong off catu daya, tegangan residual bakal ngurangan kana 75V ti √2 Un.
7. Maks. Ayeuna: ngajalankeun lancar dina 1.3 waktos dipeunteun tegangan, leuwih tegangan, kapasitas kasabaran positif jeung gelombang harmonik nu teu bisa ngaleuwihan 1 mnt unggal 24 jam.
8.Max.Current: ngajalankeun mulus dina 1.3 waktos dipeunteun tegangan, leuwih tegangan, kapasitas kasabaran positif sarta gelombang harmonik nu teu bisa 1.43 waktos dipeunteun ayeuna.
9. Baku: GB / T 112024.1-2001, IEC6087: 1997.
Kapasitor Daya Fase Papisah
Modél BAM | Tegangan dipeunteun (kV) | Kaluaran Dipeunteun (kVAr) | Kapasitansi dipeunteun (uF) | Dipeunteun Ayeuna Dina (A) |
10.5-50-1W | 10.5 | 50 | 1.444 | 4.762 |
6.35-30-1W | 6.35 | 30 | 2.368 | 4.724 |
6.35-50-1W | 6.35 | 50 | 3.946 | 7.873 |
6.3-30-1W | 6.3 | 30 | 2.4 | 4.76 |
6.3-50-1W | 6.3 | 50 | 4 | 7.9 |
6.3-100-1W | 6.3 | 100 | 8 | 15.9 |
6.3-200-1W | 6.3 | 200 | 16 | 31.7 |
6.3-300-1W | 6.3 | 300 | dua puluh opat | 47.6 |
6.3-334-1W | 6.3 | 334 | 26.8 | 53 |
10.5-50-1W | 10.5 | 50 | 1.44 | 4.8 |
10,5-100-1W | 10.5 | 100 | 2.9 | 9.5 |
10.5-150-1W | 10.5 | 150 | 4.3 | 14.3 |
10,5-200-1W | 10.5 | 200 | 5.8 | 19 |
10,5-300-1W | 10.5 | 300 | 8.67 | 28.6 |
10.5-334-1W | 10.5 | 334 | 9.65 | 31.8 |
6.35-50-1W | 6.35 | 50 | 3.95 | 7.87 |
6.35-100-1W | 6.35 | 100 | 7.89 | 15.75 |
6.35-150-1W | 6.35 | 150 | 11.84 | 23.6 |
6.35-200-1W | 6.35 | 200 | 15.78 | 31.5 |
6.35-300-1W | 6.35 | 300 | 23.68 | 47.2 |
6.35-334-1W | 6.35 | 334 | 26.36 | 52.6 |
3.81-50-1W | 3.81 | 50 | 10.96 | 13.12 |
3.81-100-1W | 3.81 | 100 | 21.9 | 26.24 |
3.81-150-1W | 3.81 | 150 | 32.9 | 39.36 |
3.81-200-1W | 3.81 | 200 | 43.8 | 52.48 |
3.81-300-1W | 3.81 | 300 | 65.8 | 78.7 |
3.81-334-1W | 3.81 | 334 | 73.2 | 87.6 |
11-100-1W | 11 | 100 | 2.63 | 9.1 |
11-150-1W | 11 | 150 | 3.95 | 13.6 |
11-200-1W | 11 | 200 | 5.26 | 18.2 |
11-300-1W | 11 | 300 | 7.89 | 27.3 |
11-334-1W | 11 | 334 | 8.79 | 30.4 |
12-100-1W | 12 | 100 | 2.2 | 8.33 |
12-150-1W | 12 | 150 | 3.3 | 12.5 |
12-200-1W | 12 | 200 | 4.4 | 16.7 |
12-300-1W | 12 | 300 | 6.64 | 25 |
12-334-1W | 12 | 334 | 7.39 | 27.8 |
6.93-100-1W | 6.93 | 100 | 6.63 | 14.4 |
6.93-150-1W | 6.93 | 150 | 9.95 | 21.7 |
6.93-200-1W | 6.93 | 200 | 13.3 | 28.9 |
6.93-300-1W | 6.93 | 300 | 19.9 | 43.3 |
6.93-334-1W | 6.93 | 334 | 22.1 | 48.2 |
6.93-400-1W | 6.93 | 400 | 26.54 | 57.74 |
6.3-100-1W | 6.3 | 100 | 8 | 15.9 |
6.3-150-1W | 6.3 | 150 | 12 | 23.8 |
6.3-200-1W | 6.3 | 200 | 16 | 31.7 |
6.3-300-1W | 6.3 | 300 | dua puluh opat | 47.6 |
6.3-334-1W | 6.3 | 334 | 26.8 | 53 |
6.6-100-1W | 6.6 | 100 | 7.3 | 15.2 |
6.6-150-1W | 6.6 | 150 | 11 | 22.7 |
6.6-200-1W | 6.6 | 200 | 14.6 | 30.3 |
6.6-300-1W | 6.6 | 300 | duapuluh dua | 45.5 |
6.6-334-1W | 6.6 | 334 | 24.4 | 50.6 |
3.81-100-1W | 3.81 | 100 | 21.9 | 26.24 |
3.81-150-1W | 3.81 | 150 | 32.9 | 39.36 |
3.81-200-1W | 3.81 | 200 | 43.8 | 52.48 |
3.81-300-1W | 3.81 | 300 | 65.8 | 78.7 |
3.81-334-1W | 3.81 | 334 | 73.2 | 87.6 |
6.35-100-1W | 6.35 | 100 | 7.89 | 15.75 |
6.35-150-1W | 6.35 | 150 | 11.84 | 23.6 |
6.35-200-1W | 6.35 | 200 | 15.78 | 31.5 |
6.35-300-1W | 6.35 | 300 | 23.68 | 47.2 |
6.35-334-1W | 6.35 | 334 | 26.36 | 52.6 |
11-100-1W | 11 | 100 | 2.63 | 5.25 |
11-150-1W | 11 | 150 | 3.95 | 7.87 |
11-200-1W | 11 | 200 | 5.26 | 10.5 |
11-300-1W | 11 | 300 | 7.9 | 15.75 |
11-100-1W | 11 | 100 | 2.63 | 5.25 |
11-150-1W | 11 | 150 | 3.95 | 7.87 |
11-200-1W | 11 | 200 | 5.26 | 10.5 |
11-300-1W | 11 | 300 | 7.9 | 15.75 |
12-100-1W | 12 | 100 | 2.2 | 4.8 |
12-150-1W | 12 | 150 | 3.3 | 7.2 |
12-200-1W | 12 | 200 | 4.4 | 9.6 |
12-300-1W | 12 | 300 | 6.64 | 14.45 |
12-100-1W | 12 | 100 | 2.2 | 4.8 |
12-150-1W | 12 | 150 | 3.2 | 7.2 |
12-200-1W | 12 | 200 | 4.4 | 9.6 |
12-300-1W | 12 | 300 | 6.64 | 14.45 |
11/√3-200-1W | 11/√3 | 200 | 15.78 | 31.5 |
11/√3-334-1W | 11/√3 | 334 | 26.36 | 52.6 |
12/√3-200-1W | 12/√3 | 200 | 13.3 | 28.9 |
12/√3-334-1W | 12/√3 | 334 | 22.1 | 48.2 |
12-200-1W | 12 | 200 | 4.4 | 16.7 |
12-334-1W | 12 | 334 | 7.39 | 27.8 |
10,5-200-1W | 10.5 | 200 | 5.8 | 19 |
10.5-334-1W | 10.5 | 334 | 9.65 | 31.8 |